Mechanical Malfunctions
Mechanical Malfunctions
A semi-automatic firearm cycles through the same basic stages every time it fires: a cartridge feeds into the chamber, the firearm fires it, the spent case extracts from the chamber, then ejects clear of the action. Most mechanical malfunctions are named after whichever of these stages didn't happen properly — which is why it helps to know the sequence before diagnosing what went wrong.
The Type 1, 2, and 3 labels from earlier modules are useful training shorthand, but they're not a full mechanical diagnosis. A "dead trigger" or a "click, no bang" can point toward several different underlying problems — recognising the pattern is the first step, not the last one.
Failure To Feed
One specific version of this is going "out of battery" — where the action hasn't fully closed. It's a useful term to know, but it doesn't cover every failure to feed; it's one possible form of it, not another name for the same thing.
Failure To Extract
Failure To Eject (Stovepipe)
Double Feed
Slamfire
This one deserves its own attention, separate from the routine stoppages above. A slamfire is an unintended discharge that happens as the action closes — the firing pin makes contact with the primer before the shooter has pressed the trigger.
This is not the same thing as a "runaway gun." A runaway gun describes sustained, uncontrolled firing — a distinct and more serious scenario in its own right, with its own causes and its own response, which isn't covered here.
Any unintended discharge — slamfire or otherwise — is reason to stop using the firearm immediately and have it properly assessed by a qualified professional before it's fired again.
An unexpected discharge, visible damage, a stoppage that keeps recurring, or genuine uncertainty about the firearm's condition all call for the same response: stop, keep the muzzle in a safe direction, and follow your range and manufacturer's guidance. Repeating the same drill on a fault you haven't identified isn't the answer.
Quick Comparison
| Malfunction | What Failed | Possible Visible Clue |
|---|---|---|
| Failure To Feed | Cartridge didn't chamber | Action not fully closed |
| Failure To Extract | Case stayed in chamber | Dead trigger, no click |
| Failure To Eject | Case didn't clear the action | Case caught at ejection port |
| Double Feed | Feed path obstructed | Dead trigger, no click |
| Slamfire | Unintended discharge on closing | Firearm fires without trigger press |
Key Takeaway
A stoppage drill can restore normal function in a lot of routine cases — but a fault that keeps recurring, or behaves unusually, needs diagnosis, not another automatic attempt at the same fix.